Back To Top

i.Profiler® plus

Fewer questions and more answers

i.Profiler® plus

Fewer questions and more answers

Autorefraction with the i.Profiler®plus

Fewer questions and more answers

 

The correct lenses can only be prescribed when you have enough information about your patient‘s eyes. Let i.Profilerplus provide you with a detailed visual profile so you can have more answers and less questions for your patient.

 

The i.Profilerplus is the 4-in-1 compact system with ocular wavefront aberrometer, autorefractometer, ATLAS corneal topographer and keratometer. The fully automated measurement procedure, with easy-to-use touch screen control, enables all measurements of both eyes in approximately 60 seconds. The eye’s refractive power distribution is analyzed and represented across the entire pupil aperture. This is what distinguishes the i.Profilerplus from conventional autorefractors and what opens the gate to ZEISS lenses with i.Scription® technology.

 

Facts at a Glance

  • High-resolution Hartmann-Shack wavefront sensor. The wavefront is sampled at 1,500 points across 7 milimeter pupil aperture
  • Adjustable chin rest for comfortable head positioning
  • Fully automated measurement procedure
  • NEW: Remotely control the ZEISS i.Profiler plus via ZEISS i.Com mobile and demonstrate the patient’s i.Scription Analysis the iPad.

  • Access to i.Scription® technology by ZEISS for improved night vision
  • Clearly structured functions enable capture, evaluation, presentation and analysis of data
  • Touch screen control enables all measurements of both eyes in 60 seconds
  • The measurement data from the i.Profiler® plus is saved on the i.Com data management system and can be used for future consultations, ordering and archiving without any need of further measurements. It interfaces with most common PMS systems for a smooth workflow guarantee. i.Com and i.Profiler® plus are available together as a package solution.
Technical Data, Wavefront  
Measuring range sphere: –20 D to +20 D
Axis 0° – 180°
Measuring surface
2.0 mm to 7.0 mm (3 zones)
No. of measuring points up to 1500
Method Hartmann-Shack
Reference wavelength 1 555 nm (ISO 24157)
Technical Data, Corneal Topography  
No. of rings
22 (18 complete rings)
No. of measuring points
3,425
Detected corneal surface
at 42.125 D
Dia. 0.75 mm to 9.4 mm
Diopters
Measurement range 25 to 65 D
Accuracy
± 0.05 D (± 0.01 mm)
Reproducibility
± 0.10 D (± 0.02 mm)
Type A Complies with 19980
Physical Data  
General dimensions
420 mm x 600 mm
Weight
30 kilograms
Power connection
100 V~ to 240 V~
Supply frequency
50 Hz to 60 Hz
Power consumption
≤ 200 VA
  • i.Profilerplus features a high- resolution wavefront measurement and corneal topography which provide you with all data needed in order to evaluate the refractive status of your patient´s eyes.
  • The analysis mode enables you to visualize the impact of different aberrations on your patient´s vision, including up to 7th Zernike aberrations. Additionally, the benefits of i.Scription® technology can be simulated through the point-spread function.

 

i.Scription® technology in your practice

Easy and smooth integration into your workflow

i.Scription technology is easy to adapt to your overall consultation process and practice workflow. Being enabled by the i.Profilerplus, this technology can be comfortably incorporated in the refractive analysis.

More details about i.Scription by ZEISS

1. Objective refraction

2. Subjective refraction

3. i.Scription technology

Videoplayer-Startimage
Sorry, this shouldn't have happened:
Video player failed to load.

Conduct an objective refraction using the i.Profilerplus, which will provide an optical “fingerprint” of your patient and will detect any aberrations in just 60 seconds.

Videoplayer-Startimage
Sorry, this shouldn't have happened:
Video player failed to load.

The values from the i.Profilerplus by ZEISS are complemented with the results from the vision exam with i.Polatest® by ZEISS to fully understand the interaction between your patient´s eyes. You can later review the values in the i.Scription review software and discuss with your patient.

Videoplayer-Startimage
Sorry, this shouldn't have happened:
Video player failed to load.

The optimized prescription data is then transferred and stored into i.Com for direct order via PMS or LOGON®.

  Single vision
stock lenses
Single vision
Rx lenses2
Progressive
lenses
Bifocal
lenses
Bifocal
lenses
Available with i.Scription® technology
3 3

Angelo Bertozzi , Ottica iVision

“The main benefit is the customer’s satisfaction and the word of mouth that they are able to generate. This is also generated by ophthalmologists when they discover that this technology is available in my optical store.”

Angelo Bertozzi , Ottica iVision, Italy

Download Brochure

ZEISS Dispensing Tools & Instruments

ZEISS Dispensing Tools & Instruments

Product Catalogue 2014/2015

 

1 US Patent 7,744,217. Other patents pending. Product designed and manufactured using Carl Zeiss Vision technology. i.Profiler® plus US Patent 7,744,217. Other patents pending. Product designed and manufactured using Carl Zeiss Vision technology.
2 including loop; available with all tints, coatings, treatments, variants
3 locally adapted

 

We use cookies on this site. Cookies are small text files that are stored on your computer by websites. Cookies are widely used and help to optimize the pages that you view. By using this site, you agree to their use. more